GDB-D Transformer Turn Ratio Tester
GDB-D Transformer turn ratio tester is designed for three phases transformer in power system and especially for Z type winding transformer and other transformers with relatively large no-load current.
-
GDZRC-10U DC Winding Resistance Tester
The measurement of DC transformer resistance is a mandatory test item in transformer manufacturing of semi-finished products, finished products factory test, installation, handover test and preventive test of power department, which can effectively find the manufacturing defects of transformer coil material selection, welding, loose connection parts, missing strands, broken wires and other hidden dangers after operation.
GDZRC-10U DC Winding resistance tester is a rapid test equipment for measuring the DC resistance of transformers, transformers, generators and motors, and it is a replacement product of single and double arm Bridges.
-
GDCL-V 20kV/10kA Impulse Combination Wave Test System Technical Solution
The equipment is according to combination wave testing requirement of the low-voltage power distribution system SPD II product, enable to generate impulse voltage (1.2/50μs) and impulse current (8/20μs), is used for grade III test and limiting voltage test of SPD and components.
-
GDCY-20B 20kV Impulse Voltage Tester (Basic Type)
GDCY-20B Programmable Automatic Impulse Voltage Tester is mainly based on TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048, JB/T 7083 and other standard requirements.
-
GDCY-1000kV/100kJ Impulse Voltage Test System
Impulse Voltage Test System is mainly used to generate lightning impulse voltage, to research and check the ability of lightning impulse ability of electric equipment. It can generate standard lightning waveform and chopping waveform.
The system can be used for impulse voltage test and other scientific research on GIS, cable, insulators, air gap, bushing, transformers etc.
-
GDCY Impulse Voltage Test System (100kV-7200kV)
Impulse Voltage Test System is mainly used for carrying out full wave lightning impulse voltage test, chopping impulse test and switching impulse test on HV apparatus such as transformers, surge arrester, insulators, bushings, capacitors, and switches. It can generate standard lightning wave, switching wave, chopping wave with wide range voltage and energy.
-
Impulse Voltage Test System – High Voltage Test Instruments
GDCY series Impulse Voltage Generator can produce a wide range of voltage and energy to simulate waveform such as lightning impulse, lightning clipped wave, switching impulse and so on, enable to carry out various forms of impulse test for high voltage power equipment, cooperate with steepening device can carry out steep wave test on the insulator (insulator string).
-
GDCY-20P Impulse Voltage Test System
The equipment is according to impulse voltage testing requirement of the low-voltage power distribution system SPD II product and solar battery, enable to generate impulse voltage (1.2/50μs), is used for grade III test and limiting voltage test of SPD and components. It is also used for impulse current test and residual voltage test of the MOV valve plate, unit and surge protective device(SPD), or used in other scientific research experiments.
The equipment uses touch screen and PLC control technology, and the main performance meets the needs of domestic and foreign SPD products and their components for various combination wave testing.
-
GDCL-Series Impulse Current Generator(Customizable)
The impulse current generator is mainly generating lightning impulse current 8/20μs, suitable for measuring residual voltage of surge arrester, varistors and other science research test.
-
GDPD-313M Portable Partial Discharge Detector
TEV and AE method is acknowledged and suitable technology to be used in online partial discharge detection.
-
GDPD-PTU PD Online Monitoring System for Oil Transformer
The aging and damage of the internal insulation of the transformer mostly starts from local discharge. The reason for local discharge is that the electric field is too concentrated at a certain point, or the electric field strength at a certain point is too large. At present, the main methods for detecting transformer local discharge faults are: UHF ultra-high frequency monitoring method, HFCT high-frequency pulse current local discharge measurement method (pulse current method), ultrasonic local discharge measurement method (ultrasonic method), and oil gas chromatography analysis method.
-
GDYT-10/100 High Precision Partial Discharge Testing System for Electrical Equipment
GDYT-10/100 Partial Discharge Test System is mainly used for testing frequency voltage insulation level of various insulation materials, insulation structure and electrical products, also as partial discharge frequency testing power supply for testing object such as transformer, mutual inductor and lightning arresters. It is widely used in electrical manufacturing, power operation departments, research institutes and universities.